Technical Data
1.Explosion-proof Type
- Standards Implemented:YX0501 series push-buttons and switch operating heads are internal components for explosion-proof enclosures without separate Ex certificates, and they must be installed inside enclosures complying with GB3836 for explosive atmospheres.
- Applicable Hazardous Areas: These operating heads cannot be used bare in explosive hazardous areas. They can be applied to relevant gas and dust hazardous zones only after being assembled within certified explosion-proof enclosures.
- Ex Marking: Gas protection: The operating heads have no independent Ex rating. The explosion-proof grade of the complete set is determined by the matched explosion-proof enclosure.
2.Product Parameters
- Product Type: Built-in operating heads for explosion-proof enclosures, including standard push-buttons, emergency-stop buttons, illuminated push-buttons, key-operated buttons and rotary switches for control-circuit operation.
- Certification: No separate Ex certification. They are internal components and shall be used together with certified explosion-proof enclosures.
- Material: Housing options of engineering plastic or metal; insulating base and metal internal contacts; illuminated versions with transparent lamp cover.
- Exposed Fasteners: No exposed fasteners, fixed by clip-in locking through panel cut-out.
- Electrical-Rated Voltage: Illuminated push-buttons support 24VDC, 240VAC. Operating heads adapt to general low-voltage control circuits.
- Electrical-Rated Current: No separate rated current on datasheet, subject to matched contact modules.
- Protection-Ingress Protection: No independent IP rating for operating heads. Protection class depends on complete explosion-proof enclosure.
- Protection-Ambient Temperature: No separate data shown, operating condition follows matched explosion-proof enclosure.
- Connection-Cable Cross-section: Screw-clamp terminals on contact modules for general control cables, no exact wire size specified in datasheet.
- Connection-Cable Entry: No cable entry on operating heads. Cables connect to rear contact terminals; cable entry is provided by outer explosion-proof enclosure.
- Connection-Cable Gland: No cable gland supplied. Glands are mounted on the explosion-proof enclosure.
3.Product Classification & Origin
HS Code: 8536500000
Country of Origin: China
4.Applicable Industries
- Suitable for: Chemical, grain-oil processing, shipbuilding, mining supporting and automation complete-set equipment industries. As built-in components inside explosion-proof control and operation boxes, they realize equipment start-stop, emergency-stop, gear switching and status indication.
- Practicality: YX0501 series covers push-buttons, emergency-stop buttons, illuminated push-buttons, key-operated buttons and rotary switches. Plastic and metal housings are available with various colors. Multiple contact configurations including NO, NC and NO+NC are supported, up to 6 contact sets can be assembled. They can be matched with indicator-light modules to satisfy diverse control logics.
- Safety Performance: Emergency-stop and key-lock structures prevent accidental operation. Metal housing provides better impact resistance. Components shall not be used bare. They shall be fitted inside explosion-proof enclosures to guarantee stable and reliable control-circuit performance.
5.Credibility
MMALATEX explosion-proof products comply with strict international standards and hold complete ATEX, IECEX and EAC certifications to ensure compliant operation in global markets. This series of explosion-proof products is engineered for extreme working conditions with IP65/IP66/IP67 protection ratings, delivering excellent resistance to water, dust and corrosion. We provide customers with in-depth supporting services, including comprehensive technical support, complete warranty services and worldwide logistics support. Wherever your project is located, MMALATEX ensures smooth project delivery and provides safe and reliable solutions for hazardous areas.
6.FAQs
Q1: What types of operating heads are included in the YX0501 series?
A1: It includes ordinary push-buttons, emergency-stop buttons, illuminated push-buttons, key-operated buttons and rotary switches.
Q2: What is the maximum number of contact sets that can be equipped for these operating heads?
A2: Up to six sets of contacts can be assembled as required.
Q3: Can YX0501 operating heads be used alone in explosive hazardous areas?
A3: No, they must be installed inside a certified explosion-proof enclosure.