Technical Data
1.Explosion-proof Type
- Standards Implemented: CENELEC, IEC, NEC
- Applicable Hazardous Areas:Suitable for Zone 1 and Zone 2, Zone 21 and Zone 22
- Ex Marking: Gas protection: Ex eb mb IIC T6 Gb; Ex tb III C T80℃ Db
2.Product Parameters
- Product Type:Panel-mount explosion-proof meter module
- Certification:Ex eb mb IIC T6 Gb; Ex tb IIIC T80℃ Db
- Material:Engineering plastic
- Exposed Fasteners:Datasheet not specified
- Electrical Specifications
- Rated Voltage:Datasheet not specified
- Rated Current:Datasheet not specified
- Protection
- Protection Degree:IP66
- Ambient Temperature:-20℃ ~ +60℃
- Connection & Input
- Cable Cross-section:Datasheet not specified
- Cable Entry:Datasheet not specified
- Cable Gland:Datasheet not specified
3.Product Classification & Origin
HS Code: 9030390000
Country of Origin: China
4.Applicable Industries
- Suitable for flammable-explosive industrial sites such as petrochemical, chemical, pharmaceutical and metallurgy.
- Practicality:Available in 48-type and 72-type housings, built-in voltmeter or ammeter optional, panel-mount design to meet various on-site monitoring requirements.
- Safety Performance:Certified with Ex eb mb IIC T6 Gb; Ex tb IIIC T80℃ Db. IP66 protection degree, working ambient temperature from -20℃ to +60℃. Corrosionresistant engineering plastic housing, suitable for Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas.
5.Credibility
MMALATEX explosion-proof products comply with strict international standards and hold complete ATEX, IECEX and EAC certifications to ensure compliant operation in global markets. This series of explosion-proof products is engineered for extreme working conditions with IP65/IP66/IP67 protection ratings, delivering excellent resistance to water, dust and corrosion. We provide customers with in-depth supporting services, including comprehensive technical support, complete warranty services and worldwide logistics support. Wherever your project is located, MMALATEX ensures smooth project delivery and provides safe and reliable solutions for hazardous areas.
6.FAQs
Q1: What hazardous areas is this explosion-proof meter module suitable for?
A1: It can be used in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous locations.
Q2: What practical options does CH0877-CP□ explosion-proof meter module provide?
A2: It has 48-type and 72-type housings, and can be equipped with built-in voltmeter or ammeter for panel mounting.
Q3: What safety-related parameters does this panel-mount explosion-proof meter module have?
A3: It is certified Ex eb mb IIC T6 Gb; Ex tb IIIC T80℃ Db with IP66 protection grade, and works at -20℃ ~ +60℃.